Please use this identifier to cite or link to this item:
https://dspace.upt.ro/xmlui/handle/123456789/1407
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bebeşelea Sterp, Adriana Ioana | - |
dc.contributor.author | Manea, Florica | - |
dc.contributor.author | Burtică, Georgeta | - |
dc.contributor.author | Nagy, L. | - |
dc.contributor.author | Nagy, G. | - |
dc.date.accessioned | 2020-04-06T13:36:55Z | - |
dc.date.accessioned | 2021-03-01T08:51:35Z | - |
dc.date.available | 2020-04-06T13:36:55Z | - |
dc.date.available | 2021-03-01T08:51:35Z | - |
dc.date.issued | 2008 | - |
dc.identifier.citation | Bebeşelea Sterp, Adriana Ioana. Electrochemical degradation and determination of 4-nitrophenol using multiple pulsed amperometry at graphite based electrodes. Timişoara: Editura Politehnica, 2008 | en_US |
dc.identifier.uri | http://primo.upt.ro:1701/primo-explore/search?query=any,contains,Electrochemical%20degradation%20and%20determination%20of%204-nitrophenol%20using%20multiple%20pulsed%20amperometry%20at%20graphite%20based%20electrodes&tab=default_tab&search_scope=40TUT&vid=40TUT_V1&lang=ro_RO&offset=0 Link Primo | - |
dc.description.abstract | The electrochemical degradation and determination of 4-nitrophenol (4-NP) by multiple pulsed amperometry (MPA) using rotating spectral graphite disc (SG) and expanded graphite-epoxy composite (EG-Epoxy) electrodes is reported.The MPA performance for 4-NP degradation was assessed as function of time for both electrodes, the best results were achieved for SG electrode. The optimal MPA parameters at the both types of graphite based electrodes were establised for 4-NP detection , i.e. the detection potential was 1.1 V ( versus Ag/AgCl) for 50 ms detection time and 1.4 V (versus Ag/AgCl) oxidation potential as clean potential for 150 ms clean time. The proposed method showed the better analytical performance for EG-Epoxy electrode for the determination 4-NP, with a linear range of 0.2 – 1 mM, detection limits of 0.05 - 0.1 mM and recovery degree of 92.4 – 94.6 %. The application of this method to a drinking water spiked with various quantities of nitrophenol was demonstrated and validated using UV photometric determination method at λ=398 nm for 4-NP. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Timişoara : Editura Politehnica | en_US |
dc.relation.ispartofseries | Seria chimie şi ingineria mediului,;Tom 53(67), fasc. 1-2 (2008) | - |
dc.subject | Protecţia mediului -- Articol | en_US |
dc.subject | Multiple pulsed amperometry | en_US |
dc.subject | Graphite-epoxy composite | en_US |
dc.subject | 4-nitrophenol | en_US |
dc.title | Electrochemical degradation and determination of 4-nitrophenol using multiple pulsed amperometry at graphite based electrodes [articol] | en_US |
dc.type | Article | en_US |
Appears in Collections: | Articole științifice/Scientific articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
BUPT_ART_Bebeșelea_f.pdf | 135.45 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.