Title: | A new 450 kW electric motor - it can withstand temperature of 400°C over a period of two hours [articol] |
Authors: | Pucher, Robert Pucher, Karl |
Subjects: | Fire Road tunnel Heat resistance |
Issue Date: | 2006 |
Publisher: | Timişoara: Editura Politehnica |
Citation: | Pucher, Robert. A new 450 kW electric motor - it can withstand temperature of 400°C over a period of two hours. Timişoara: Editura Politehnica, 2006 |
Series/Report no.: | Buletinul ştiinţific al Universităţii „Politehnica” din Timişoara, România. Seria electronică şi telecomunicaţii, Tom 51(65), fasc. 1 (2006), p. 9-10 |
Abstract: | Due to national guideline RVS 9.261, a heat resistance of 400°C over a period of 120 minutes has to be verified for exhaust ventilators in Austria. For this reason a 450 kW electric motor was tested in a chamber in a 400°C environment. The test gave evidence that the motor could be operated under load for approximately 165 minutes without serious problems. |
URI: | http://primo.upt.ro:1701/primo-explore/fulldisplay?docid=40TUT000135887&context=L&vid=40TUT_V1&lang=ro_RO&search_scope=40TUT&adaptor=Local%20Search%20Engine&tab=default_tab&query=any,contains,A%20new%20450%20kW%20electric%20motor%20-%20it%20can%20withstand%20temperature%20of%20400%C2%B0C%20over%20a%20period%20of%20two%20hours&sortby=rank&offset=0 Link Primo |