Please use this identifier to cite or link to this item: https://dspace.upt.ro/xmlui/handle/123456789/7038
Title: A performance comparison study of grid-tied wind farm without and with battery energy storage system [articol]
Authors: Shankar, M.
Kumudini Devi, R. P.
Subjects: Generic battery model
Total harmonic distortion
Issue Date: 2019
Publisher: Timișoara : Editura Politehnica
Citation: Shankar,M.; Kumudini Devi ,R.P.: A performance comparison study of grid-tied wind farm without and with battery energy storage system. Timişoara: Editura Politehnica, 2019.
Series/Report no.: Journal of Electrical Engineering;Vol 19 No 3
Abstract: While integrating the Wind Energy Conversion System to the power grid, power quality issues like power unbalance and harmonic distortion arises. The same can be mitigated by adding battery energy storage system in the DC bus of Class C & D type variable-speed Wind Turbine Generator systems. In simulation studies, the battery energy storage system is represented as a battery bank (direct current sources in series parallel combinations) without considering its actual dynamics. This paper presents a part of the research work that aims at considering the thermodynamics of the battery energy storage by developing a generic model that includes the integration of electrochemical, analytical and electric circuit model approach. To this perspective, a wind farm, AC-DC rectifier, Battery Generic Model, Battery Charge/Discharge Control Logic, DC-AC inverter and open loop radial grid model are developed in PSCAD/EMTDC. Simulations are performed without and with battery energy storage. Mitigation of power quality aspects like power unbalance and harmonic distortion are validated from simulation results. An experimental setup to emulate the power quality issues arising of Class C & D type WTGs and its mitigation using battery energy storage without grid integration is also presented. Vanadium Redox Flow Battery model is used in the simulation study. Both the simulation and emulation results justify power quality issues mitigation with battery energy storage.
URI: https://dspace.upt.ro/xmlui/handle/123456789/7038
ISSN: 1582-4594
Appears in Collections:Articole științifice/Scientific articles

Files in This Item:
File Description SizeFormat 
BUPT_ART_Shankar_f.pdf538.2 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.