Please use this identifier to cite or link to this item: https://dspace.upt.ro/xmlui/handle/123456789/7119
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAhmad, Mohammad-
dc.contributor.authorKhan, B. H.-
dc.contributor.authorJha, Anil Kumar-
dc.date.accessioned2025-02-07T06:59:28Z-
dc.date.available2025-02-07T06:59:28Z-
dc.date.issued2019-
dc.identifier.citationAhmad,Mohammad; Khan,B.H.; Jha,Anil Kumar. Comparative Analysis of Two Inverter Topologies Considering Either Battery or Solar PV as DC Input Sources. Timişoara: Editura Politehnica, 2019.en_US
dc.identifier.issn1582-4594-
dc.identifier.urihttps://dspace.upt.ro/xmlui/handle/123456789/7119-
dc.description.abstractIn this paper, a comparative analysis of two inverter topologies is carried out for the same RL load. The first topology uses cascaded H-Bridge (CHB) Inverter. The second uses new Multi-level Scheme having Two Level Modules and H-Bridge. Both topologies are studied under two types of input sources: (i) battery and (ii) solar PV panel. The simulation is done in SIMULINK / MATLAB Software. The Total Harmonic Distortion in output load voltage / current and Active / Reactive Powers obtained from both the schemes considering one of the two types of inputs, battery and solar PV panel are compared. It is found that for low input voltage range second scheme is better as it has low THD. And for high input voltage range, first scheme has fewer harmonic. However, the Active power and reactive power are more in new multilevel scheme. As the number of switches is more in cascaded inverter scheme, hence it is costly and has more switching losses for the same input voltage. It is also observed that the results are almost similar for both types of input sources. A capacitor is used across PV panel to reduce spikes in load voltage waveform and hence improve THD.en_US
dc.language.isoenen_US
dc.publisherTimișoara : Editura Politehnicaen_US
dc.relation.ispartofseriesJournal of Electrical Engineering;Vol 19 No 1-
dc.subjectH-Bridge inverteren_US
dc.subjectLevel Module (LM)en_US
dc.subjectMultilevel inverteren_US
dc.subjectPower Qualityen_US
dc.subjectTotal Harmonic Distortion (THD)en_US
dc.titleComparative Analysis of Two Inverter Topologies Considering Either Battery or Solar PV as DC Input Sources [articol]en_US
dc.typeArticleen_US
Appears in Collections:Articole științifice/Scientific articles

Files in This Item:
File Description SizeFormat 
BUPT_ART_Ahmad_f.pdf1.07 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.