Please use this identifier to cite or link to this item: https://dspace.upt.ro/xmlui/handle/123456789/7272
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSangeetha, S.-
dc.contributor.authorMahalakshmi, R.-
dc.date.accessioned2025-02-25T08:48:47Z-
dc.date.available2025-02-25T08:48:47Z-
dc.date.issued2018-
dc.identifier.citationSangeetha,S.; R. Mahalakshmi,R.; Effective power quality management in grid connected wind energy system through performance enhanced STATCOM. Timişoara: Editura Politehnica, 2018.en_US
dc.identifier.issn1582-4594-
dc.identifier.urihttps://dspace.upt.ro/xmlui/handle/123456789/7272-
dc.description.abstractPower system accompanied by the drastic number of challenges like dynamic change in the system, power quality issues and power flow are found to be more prominent ingrid-connected renewable system. Power quality management which arises due to non-linear loads connected to the system. Power quality management is the major factor for renewable application due to stochastic nature affects the operation of sensitive applications. To maintain appropriate power quality traditional approaches uses Static synchronous compensator (STATCOM) incorporated with Proportional-Integral (PI) controller by the principle of point of common coupling (PCC). In this research to improve the power quality management of renewable system traditional PI controller in STATCOM is replaced with fuzzy logic controller (FLC), artificial neural network (ANN) controller and adaptive neuro-fuzzy inference system (ANFIS) controller. Replacement of FLC, ANN in PI controller approximates the linear functionality of the STATCOM for maintaining appropriate power level. The proposed approach performance is evaluate using MATLAB/SIMULINK environment with both synchronous Generator and doubly fed Induction Generator. Simulation results exhibit that replacement of controller in PI controller provides compensation current in PCC in an acceptable range. Further, the incorporation of controllers reduced the Total Harmonic Distortion (THD) value at a significant amount for ANFIS controller.en_US
dc.language.isoenen_US
dc.publisherTimișoara : Editura Politehnicaen_US
dc.relation.ispartofseriesJournal of Electrical Engineering;Vol 18 No 3-
dc.subjectSynchronous generatoren_US
dc.subjectStatic synchronous compensatoren_US
dc.subjectThe point of common couplingen_US
dc.subjectWind energy conversion systemen_US
dc.subjectFuzzy logic controlleren_US
dc.subjectArtificial neural networken_US
dc.titleEffective power quality management in grid connected wind energy system through performance enhanced STATCOM [articol]en_US
dc.typeArticleen_US
Appears in Collections:Articole științifice/Scientific articles

Files in This Item:
File Description SizeFormat 
BUPT_ART_Sangeetha_f.pdf970.97 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.