Please use this identifier to cite or link to this item: https://dspace.upt.ro/xmlui/handle/123456789/7590
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRashad, Mohamed-
dc.contributor.authorElghaffar, Amer Nasr A.-
dc.date.accessioned2025-07-22T05:58:19Z-
dc.date.available2025-07-22T05:58:19Z-
dc.date.issued2024-
dc.identifier.citationRashad,Mohamed; Elghaffar, Amer Nasr A.: Electrical protection and control system development steps, an overview. Timişoara: Editura Politehnica, 2024. Disponibil la: https://doi.org/10.59168/CZFF3279en_US
dc.identifier.issn2067 – 3809-
dc.identifier.urihttps://search.crossref.org/search/works?q=10.59168%2FCZFF3279&from_ui=yes Link DOI-
dc.identifier.urihttps://acta.fih.upt.ro/-
dc.identifier.urihttp://primo.upt.ro:1701/primo-explore/fulldisplay?docid=40TUT000154066&context=L&vid=40TUT_V1&lang=ro_RO&search_scope=40TUT&adaptor=Local%20Search%20Engine&tab=default_tab&query=any,contains,Electrical%20protection%20and%20control%20system%20development%20steps,%20an%20overview&sortby=rank&offset=0 Link PRIMO-
dc.description.abstractA power system is not only capable to meet the present load but also has the flexibility to meet the future demands. A power system is designed to generate electric power in sufficient quantity, to meet the present and estimated future demands of the users in a particular area, to transmit it to the areas where it will be used and then distribute it within that area, on a continuous basis. Using the optimum protection and control systems with the high voltage substations are considered as the main objectives to save the system is reliable and curate operation. The protection system in high voltage substation had started by the electro–mechanical relays which improved to electrostatic relays and updated to the numerical protection relays. The switching and control of the substations had started depending on the manpower for operation and supervising the system which improved to depend on the SCADA system. This paper introduces the steps and the operation function of using the electro–mechanical, electrostatic designs and numerical relays to protect the electrical equipment in high voltage substations. Also, this paper study the improvement of the control and supervising the high voltage substations that reached now to depend on the IEC 61850 communication protocol for the optimum automation system.en_US
dc.language.isoenen_US
dc.publisherTimişoara: Editura Politehnicaen_US
dc.relation.ispartofseriesActa Technica Corviniensis – Bulletin of Engineering;Tome XVII [2024]. Fascicule 1 [January – March]-
dc.subjectHigh voltage substationsen_US
dc.subjectProtection systemen_US
dc.subjectNumerical relaysen_US
dc.subjectSASen_US
dc.subjectIEC 61850en_US
dc.titleElectrical protection and control system development steps, an overview [articol]en_US
dc.typeArticleen_US
Appears in Collections:Articole științifice/Scientific articles

Files in This Item:
File Description SizeFormat 
BUPT_ART_Rashad_f.pdf1.31 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.