DSpace Repository

Active compensation in a low voltage network comprises power factor correction capacitor with harmonic current producing loads [articol]

Show simple item record

dc.contributor.author Elgendy, Ossama M.
dc.contributor.author Abass, A.-M. A.
dc.contributor.author Mahmoud, Ahmed M.A.
dc.contributor.author Alkoshery, A.D.
dc.date.accessioned 2020-04-10T09:05:58Z
dc.date.accessioned 2021-03-01T08:39:31Z
dc.date.available 2020-04-10T09:05:58Z
dc.date.available 2021-03-01T08:39:31Z
dc.date.issued 2006
dc.identifier.citation Elgendy, Ossama M.. Active compensation in a low voltage network comprises power factor correction capacitor with harmonic current producing loads. Timişoara: Editura Politehnica, 2006 en_US
dc.identifier.uri http://primo.upt.ro:1701/primo-explore/search?query=any,contains,Active%20compensation%20in%20a%20low%20voltage%20network%20comprises%20power%20factor%20correction%20capacitor%20with%20harmonic%20current%20producing%20loads&tab=default_tab&search_scope=40TUT&vid=40TUT_V1&lang=ro_RO&offset=0 Link Primo
dc.description.abstract In this paper, a compensation strategy for a low- voltage network comprises a power factor correction capacitor and non- linear loads connected to the same load-buss is investigated. The loads in the low- voltage network can be classified, from the harmonics point of view, into harmonic current producing loads, harmonic voltage producing loads and harmonic sensitive loads. The compensation in the low -voltage side of a power network is more reliable, efficient, economic and straightforward. The idea here stems from the fact that when applying a pollution treatment for a river, it is not practical, in all cases, to establish a treatment unit across the river. The more reliable solution is to clean and purify those outlets discharging into the river individually. If this concept could be generalized in industry, it is logical that the cost of applying the proposed compensation strategy to an industrial unit would not be comparable either to the price of the production line or to the penalties paid to authority on the long run. In the next sections, the proposed strategy will be clarified through analysis, design and simulation using a shunt active power filter. en_US
dc.language.iso en en_US
dc.publisher Timişoara: Editura Politehnica en_US
dc.relation.ispartofseries Seria electronică şi telecomunicaţii, Tom 51(65), fasc. 1 (2006)
dc.title Active compensation in a low voltage network comprises power factor correction capacitor with harmonic current producing loads [articol] en_US
dc.type Article en_US