DSpace Repository

Nickel removal from aqueous solutions by flotation with cationic collector. Determination of the optimum separation conditions [articol]

Show simple item record

dc.contributor.author Turtureanu, A
dc.date.accessioned 2020-04-14T15:42:17Z
dc.date.accessioned 2021-03-01T08:39:43Z
dc.date.available 2020-04-14T15:42:17Z
dc.date.available 2021-03-01T08:39:43Z
dc.date.issued 2008
dc.identifier.citation Turtureanu, A. Nickel removal from aqueous solutions by flotation with cationic collector. Determination of the optimum separation conditions. Timişoara: Editura Politehnica, 2008 en_US
dc.identifier.uri http://primo.upt.ro:1701/primo-explore/search?query=any,contains,Nickel%20removal%20from%20aqueous%20solutions%20by%20flotation%20with%20cationic%20collector.%20Determination%20of%20the%20optimum%20separation%20conditions&tab=default_tab&search_scope=40TUT&vid=40TUT_V1&lang=ro_RO&offset=0http://primo.upt.ro:1701/primo-explore/search?query=any,contains,Nickel%20removal%20from%20aqueous%20solutions%20by%20flotation%20with%20cationic%20collector.%20Determination%20of%20the%20optimum%20separation%20conditions&tab=default_tab&search_scope=40TUT&vid=40TUT_V1&lang=ro_RO&offset=0 Link Primo
dc.description.abstract Nickel removal from dilute aqueous solutions is studied for environmental protection and nickel recovery. The paper presents the removal of nickel from dilute aqueous solutions by flotation (dispersed-air-flotation) at a laboratory scale, using a cationic collector (octadecilamine). The optimum values of the main parameters influencing this process were determined. (pH of Ni(II) solutions, molar ratio octadecilamine:Ni(II), air flow rate, flotation time, temperature and initial concentration of metal ions in sample). An atomic absorption spectrophotometer PYE UNICAM model SP 1900 was used to determine the nickel content of the solutions. The nickel removal efficiency was calculated with the relation: R% = (1- C/C₀)⋅100, where C₀ and C are initial and after flotation concentrations of nickel ions in solutions. Using the optimal conditions, high removal degree of nickel (> 98%) was obtained. en_US
dc.language.iso en en_US
dc.publisher Timişoara : Editura Politehnica en_US
dc.relation.ispartofseries Seria chimie şi ingineria mediului;Tom 53(67), fasc. 1-2 (2008)
dc.subject Nickel en_US
dc.subject Removal en_US
dc.subject Flotation en_US
dc.subject Octadecilamine en_US
dc.title Nickel removal from aqueous solutions by flotation with cationic collector. Determination of the optimum separation conditions [articol] en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account