DSpace Repository

High power voltage multiplier (VM) PFC Converter with inherent ZCS Characteristics and high step-ip gain for enhanced low-line efficiency [articol]

Show simple item record

dc.contributor.author Mohanty, Pratap Ranjan
dc.contributor.author Panda, Anup Kumar
dc.contributor.author Patnaik, Nishant
dc.date.accessioned 2024-02-06T13:13:03Z
dc.date.available 2024-02-06T13:13:03Z
dc.date.issued 2021
dc.identifier.citation Mohanty; Pratap Ranjan; Panda, Anup Kumar; Patnaik, Nishant. High power voltage multiplier (VM) PFC Converter with inherent ZCS Characteristics and high step-ip gain for enhanced low-line efficiency. Timişoara: Editura Politehnica, 2021. Disponibil la: https://doi.org/10.59168/DMXQ7599 (Article DOI Link) en_US
dc.identifier.uri http://www.jee.ro/index.php/jee/issue/view/81 Link Journal
dc.identifier.uri https://search.crossref.org/search/works?q=10.59168%2FDMXQ7599+&from_ui=yes Link DOI
dc.description.abstract In this paper, a Voltage Multiplier (VM) converter configuration has been designed for high Power PFC application, ensuring reduced losses and high system efficiency.The conventional PFC system is improved with adding VM circuit configuration that enhances the static gain features with moderate duty ratio (D), and hence, the reverse recovery (RR) issue is resolved. The VM section inherently adds two main specific features of clamping behavior and ZCS phenomenon to the PFC system. An experimental prototype of 2 kW, 600 V VM PFC converter configuration is designed and its effectiveness is validated under low line input of 100 V , operating at a high duty ratio, D = 0:67. The Real-Time Interface (RTI) feature of dSPACE1104 and MATLAB/Simulink are used to give the control signal for the verification of the system. Always, less than half of the output voltage (300 V ) appears across the switches of the converter, hence, voltage stress of the switch is minimized. Also, ZCS phenomenon is evident during switching commutations due to the snubber circuit behavior of the resonant tank, included in the proposed PFC converter. Hence, the overall system efficiency is improved. Furthermore, higher system efficiency is maintained for different rating which has been tested in this research work. en_US
dc.language.iso en en_US
dc.publisher Timișoara : Editura Politehnica en_US
dc.relation.ispartofseries Journal of Electrical Engineering ; Vol 21, No 3
dc.source.uri http://www.jee.ro/index.php/jee/issue/view/81
dc.subject Voltage multiplier en_US
dc.subject Power factor correction en_US
dc.subject Boost Converter
dc.title High power voltage multiplier (VM) PFC Converter with inherent ZCS Characteristics and high step-ip gain for enhanced low-line efficiency [articol] en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account