Constant voltage and frequency operation of a two windings single phase self-excited induction generator [articol]

Show simple item record

dc.contributor.author Hanafy, H.H.
dc.contributor.author Soufi, Heba M.
dc.contributor.author Saleh, Amr A.
dc.contributor.author Magdy, B. Eteiba
dc.date.accessioned 2024-09-25T06:48:57Z
dc.date.available 2024-09-25T06:48:57Z
dc.date.issued 2020
dc.identifier.citation Hanafy, H.H.: Soufi, Heba M.; Saleh, Amr A.; Magdy, B. Eteiba. Constant voltage and frequency operation of a two windings single phase self-excited induction generator. Timişoara: Editura Politehnica, 2020. en_US
dc.identifier.issn 1582-4594
dc.identifier.uri https://dspace.upt.ro/xmlui/handle/123456789/6679
dc.description.abstract This paper presents the steady-state and dynamic analysis of a two windings single phase self-excited induction generator (TWSPSEIG) equipped with an excitation capacitor and a compensation capacitor for operation at constant rated load voltage and frequency irrespective the no load or different load conditions. The performance equations at steady-state conditions are obtained by applying loop impedance method via the exact equivalent circuit models of the TWSPSEIG based on the double revolving field theory. Rather than the conventional methods of analysis, to get two non-linear higher order equations keeping the magnetizing reactance and the frequency as unknowns, these equations are rearranged to get two second order equations keeping the values of the excitation capacitor and the compensation capacitor as unknowns for given values of generator parameters, prime mover speed, output frequency and load impedance. The two second order equations are solved using simple iterative method to calculate the optimum values of the two capacitors under the constrains that the load voltage and frequency are constant at rated values. The range of capacitors variations required for maintaining constant rated load voltage and frequency while supplying variable load at variable prime mover speed are calculated. The steady-state results are confirmed by developing a dynamic model of the TWSPSEIG incorporating its nonlinearity behavior and various no-load and load conditions. The dynamic behavior of the TWSPSEIG at different operating conditions proves the capabilities of the proposed configuration and calculations method to maintain both the load voltage and frequency constants. en_US
dc.language.iso en en_US
dc.publisher Timișoara : Editura Politehnica en_US
dc.relation.ispartofseries Journal of Electrical Engineering;Vol 20 No 1
dc.subject Single phase self-excited induction generator en_US
dc.subject Voltage control en_US
dc.subject Frequency control en_US
dc.subject Steady-state and dynamic models en_US
dc.title Constant voltage and frequency operation of a two windings single phase self-excited induction generator [articol] en_US