Please use this identifier to cite or link to this item: https://dspace.upt.ro/xmlui/handle/123456789/3597
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDogariu, Adrian-Ioan-
dc.date.accessioned2020-11-02T13:54:28Z-
dc.date.accessioned2021-03-01T11:10:55Z-
dc.date.available2020-11-02T13:54:28Z-
dc.date.available2021-03-01T11:10:55Z-
dc.date.issued2009-
dc.identifier.citationDogariu, Adrian-Ioan. Seismic retrofitting techniques based on metallic materials of RC and/or masonry buildings. Timişoara: Editura Politehnica, 2009en_US
dc.identifier.isbn9789736258497-
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/3597-
dc.description.abstractTwo innovative strengthening solutions for masonry walls are presented. First one consists in sheeting some steel or aluminium plates either on both sides or on one side of the masonry wall. Metallic plates are fixed either with prestressed steel ties, or using chemical anchors. The second one is derived from the FRP technique, but applies a steel wire mesh bonded with epoxy resin to the masonry wall. Both these techniques are described together with the experimental program carried out at the “Politehnica” University of Timisoara on the aim to validate them. The Performance Based Evaluation and Retrofitting Design of masonry buildings is addressed. General principles, the acceptability criteria associated to different performance level and intervention strategies are reviewed. The innovative intervention technique is evaluated in terms of strength and ductility performance criteria. In the second part of the paper this technique is applied to retrofitting and historical masonry building. A building designed according only to geometrical consideration (as typical at the beginning of the XX century) has been evaluated and consolidated applying a strengthening solution based on metallic sheathing. On this, purpose a Performance Based Seismic Evaluation procedure was applied using an equivalent FE model. This model, experimentally and numerical calibrated, to simulate the behaviour of masonry shear walls strengthened with metal sheathing is applied by ABAQUS code, in order to establish the acceptance criteria, performance levels and building performance.en_US
dc.language.isoenen_US
dc.publisherTimişoara: Editura Politehnicaen_US
dc.relation.ispartofseries5 Inginerie Civilă;37-
dc.subjectConstrucţii metaliceen_US
dc.subjectStructuri metaliceen_US
dc.subjectTeză de doctoraten_US
dc.titleSeismic retrofitting techniques based on metallic materials of RC and/or masonry buildingsen_US
dc.typeThesisen_US
Appears in Collections:Teze de doctorat/Phd theses

Files in This Item:
File Description SizeFormat 
BUPT_TD_Dogariu Adrian.pdf79.76 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.