Title: Study on influence of SiO2 nano particles on the failure of XLPE underground cables due to electrical treeing [articol]
Authors: Kalaivanan, C.
Chandrasekar, S.
Subjects: XLPE
Electrical treeing
Dielectric Properties
Breakdown time
Nano filler
Issue Date: 2020
Publisher: Timișoara : Editura Politehnica
Citation: Kalaivanan, C.; Chandrasekar, S.: Study on influence of SiO2 nano particles on the failure of XLPE underground cables due to electrical treeing. Timişoara: Editura Politehnica, 2020.
Series/Report no.: Journal of Electrical Engineering;Vol 20 No 3
Abstract: In the present work, electrical treeing analysis of the pure and nano filled Cross Linked Polyethylene (XLPE) material has been studied. The electrical tree inception time, breakdown time and propagation speed of the nano filled XLPE insulation has been investigated. Nano Silicone Oxide (SiO2) was used as a filler material. Nano-fillers were added at different concentrations of 1% and 3% by weight in the base material. Laboratory experiments were conducted as per IEC procedures at 12 kV AC voltage magnitude. Tree structure was observed for all the test samples. Scanning Electron Microscope (SEM) carried out for understanding the dispersion of nano fillers in the nano filled material. Thermo Gravimetric Analysis (TGA), volume resistivity, capacitance and dielectric constant test were carried out to understand the physical and chemical characteristics of the nano filled XLPE material.
URI: https://dspace.upt.ro/xmlui/handle/123456789/6606
ISSN: 1582-4594
Appears in Collections:Articole științifice/Scientific articles

Files in This Item:
File Description SizeFormat 
BUPT_ART_Kalaivanan_f.pdf986.94 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.