https://dspace.upt.ro/xmlui/handle/123456789/7047| Titlu: | Transient analysis of an interconnected power system incorporating SMEs along with electric vehicle utilizing optimized controller tuning [articol] |
| Autori: | Satheesh Kumar, S. Gnanambal, K. |
| Subiecte: | Load frequency control (LFC) Fraction order proportional integral derivative controller (FOPID) Super conducting Magnetic Storage device (SMES) Flower Pollination Algorithm (FPA) Differential Evolution (DE) Particle Swarm optimization (PSO) |
| Data publicării: | 2019 |
| Editura: | Timișoara : Editura Politehnica |
| Citare: | Satheesh Kumar,S.; Gnanambal,K.: Transient analysis of an interconnected power system incorporating SMEs along with electric vehicle utilizing optimized controller tuning. Timişoara: Editura Politehnica, 2019. |
| Serie/Nr. raport: | Journal of Electrical Engineering;Vol 19 No 3 |
| Abstract: | In present power scenario, the generation of electrical power has been increasing day by day, in order to meet out the power demand of the end users. The main objective of the power sector is to provide reliable power with reduced losses and external load disturbances. Load frequency controller gains importance in mitigating the frequency deviation and tie power flow variations within stipulated time. The Proposed paper deals with development of FOPID controller to improve the System Performance of Interconnected Power System Network. An attempt is made in paper wherein the performance of FOPID controller is validated using the flower pollination Algorithm along with Differential Evolution and particle Swarm optimization technique applied to a large scale power system network .To escalate the performance of proposed controller, the system is being analyzed with implementation of super conducting magnetic energy storage device (SMES) and Electrical vehicle to study the impact of ancillary controllers in load frequency control. The objective function relies on reduction ITAE applied to three area power system network. |
| URI: | https://dspace.upt.ro/xmlui/handle/123456789/7047 |
| ISSN: | 1582-4594 |
| Colecţia: | Articole științifice/Scientific articles |
Fişierele documentului:
| Fişier | Descriere | Mărime | Format | |
|---|---|---|---|---|
| BUPT_ART_Satheesh Kumar_f.pdf | 967.94 kB | Adobe PDF | Vizualizare/Deschidere |
Documentele din DSpace sunt protejate de legea dreptului de autor, cu toate drepturile rezervate, mai puţin cele indicate în mod explicit.