Utilizaţi acest identificator pentru a cita sau a face link la acest document:
https://dspace.upt.ro/xmlui/handle/123456789/7262| Titlu: | Investigation of performance of standalone solar PV system with KY – SR buck boost converter using fl based direct M.PPT control method [articol] |
| Autori: | Alagammal, S. Prabha, N. Rathina |
| Subiecte: | Standalone Solar PV systems (SSPVS) Positive KY-SR Buck-Boost converter Fuzzy Logic based Maximum Power Point Tracking (FLMPPT) Arduino UNO microcontroller Resistive Load |
| Data publicării: | 2018 |
| Editura: | Timișoara : Editura Politehnica |
| Citare: | Alagammal,S.; Prabha,N. Rathina. Investigation of performance of standalone solar PV system with KY – SR buck boost converter using fl based direct M.PPT control method. Timişoara: Editura Politehnica, 2018. |
| Serie/Nr. raport: | Journal of Electrical Engineering;Vol 18 No 3 |
| Abstract: | Energy efficiency and reliability are the major concern in the operation of the Standalone Solar PV Power Systems (SSPVS). These concerns induced to develop the proposed system which includes PV module, positive output KY – SR buck boost converter, Fuzzy Logic Controller (FLC) and a resistive load. In this work, FL based Maximum Power Point Tracking (MPPT) for proposed converter in SSPVS with direct duty cycle control strategy for resistive loads has been employed. The proposed strategy is able to track the maximum power delivered to the load accurately and rapidly without oscillation and satisfied dynamic performance, irrespective of varying solar insolation levels. MATLAB and MULTISIM tools were employed for simulation studies. In addition, both high and low power PV panel of MS24250 and SPP030201200 has been chosen with maxi mum power rating of 252.5 and 20 watts to investigate the system performance. However, the prototype model has been developed and tested using SPP030201200 PV panel installed in our laboratory, wherein the Arduino UNO microcontroller was employed to provide the control signals to the converter. Experimental results shows that the proposed system yields desired output voltages with better efficiency by means of simplified control algorithm. |
| URI: | https://dspace.upt.ro/xmlui/handle/123456789/7262 |
| ISSN: | 1582-4594 |
| Colecţia: | Articole științifice/Scientific articles |
Fişierele documentului:
| Fişier | Descriere | Mărime | Format | |
|---|---|---|---|---|
| BUPT_ART_Alagammal_f.pdf | 1.35 MB | Adobe PDF | Vizualizare/Deschidere |
Documentele din DSpace sunt protejate de legea dreptului de autor, cu toate drepturile rezervate, mai puţin cele indicate în mod explicit.