Abstract:
Multilevel converters are essential
for high capacity turbines and medium voltage
generation. This paper presents an optimum
maximum power Pmax(wopg technique to guaranty
an optimal reference speed. PI controller and fuzzy
logic controller for both direct torque control in
machine side converter and direct power control of
grid side converter with diode clamped five—level
converter are implemented. The use of PI controller
for both direct torque control and direct power
control with multilevel converters is expected to
decrease steady state error. It may increase peak
overshoot and steady state time. And it cannot
handle uncertainty (system parameters, sensor
measurement). Replacing PI controller with fuzzy
logic controller will decrease peak overshoot,
steady state time and it can handle uncertainty.
Direct torque control with fuzzy speed controller
for multilevel converters improves the performance
of wind turbine (MPPT) and Squirrel cage
induction generator (speed, flux, torque and
current) despite wind variation. Direct power
control with fuzzy dc voltage controller for
multilevel converters will improve power quality
(the current injected to utility—grid). A comparison
between PI controller and fuzzy logic controller for
both machine side converter and grid side converter
with diode clamped five—level converter has been
done.