Titlu: | Power quality improvement in wind integrated distribution system using hybrid fuzzy genetic controller [articol] |
Autori: | Williams, A. Subanth Mani Malar, R. Suja Ahilan, T. |
Subiecte: | Dynamic Voltage Restorer Distribution static compensator; Fuzzy Genetic Algorithm Voltage Sag Voltage Swell Power Quality Improvement Harmonic Reduction |
Data publicării: | 2020 |
Editura: | Timișoara : Editura Politehnica |
Citare: | Williams, A. Subanth; Mani Malar, R. Suja; Ahilan, T.: Power quality improvement in wind integrated distribution system using hybrid fuzzy genetic controller. Timişoara: Editura Politehnica, 2020. |
Serie/Nr. raport: | Journal of Electrical Engineering;Vol 20 No 1 |
Abstract: | The distribution systems are transitioning from passive to active with the adaptation of storage, smart-grid, and distribution generation technologies. The reliability of the system can be improved due to the novel controllers, switches, and communication equipment. The common power quality issues are harmonics, signalling voltages, voltage fluctuations, voltage dips, voltage unbalance, power frequency variation, and induced low frequency voltages. These problems can degrade the output power level. To overcome the above problems through the power quality devices like Dynamic voltage restorer (DVR), distribution static compensator (DSTATCOM), and unified power quality conditioner (UPQC). The power quality mitigation technique includes the controller placement and it is named by Hybrid term of fuzzy-genetic controller (FG). Voltage sag, swell, and harmonics, such kind of problems have been analysed in this paper. The results are compared with the existing controllers. The proposed results are load voltage, injected voltage, and generated voltages are taken out. The performance of power quality is analysed through the multi compensating devices, and it is implemented in MMATLAB/SIMULINK. Thus the proposed system can yield the better results instead of the harmonic which is appeared in DVR, DSTATCOM, and UPQC are 0.008231%, 0.0831%, and 0.004308% respectively. |
URI: | https://dspace.upt.ro/xmlui/handle/123456789/6633 |
ISSN: | 1582-4594 |
Colecţia: | Articole științifice/Scientific articles |
Fişierele documentului:
Fişier | Descriere | Mărime | Format | |
---|---|---|---|---|
BUPT_ART_Williams_f.pdf | 678.75 kB | Adobe PDF | Vizualizare/Deschidere |
Documentele din DSpace sunt protejate de legea dreptului de autor, cu toate drepturile rezervate, mai puţin cele indicate în mod explicit.