Please use this identifier to cite or link to this item: https://dspace.upt.ro/xmlui/handle/123456789/6633
Title: Power quality improvement in wind integrated distribution system using hybrid fuzzy genetic controller [articol]
Authors: Williams, A. Subanth
Mani Malar, R. Suja
Ahilan, T.
Subjects: Dynamic Voltage Restorer
Distribution static compensator;
Fuzzy Genetic Algorithm
Voltage Sag
Voltage Swell
Power Quality Improvement
Harmonic Reduction
Issue Date: 2020
Publisher: Timișoara : Editura Politehnica
Citation: Williams, A. Subanth; Mani Malar, R. Suja; Ahilan, T.: Power quality improvement in wind integrated distribution system using hybrid fuzzy genetic controller. Timişoara: Editura Politehnica, 2020.
Series/Report no.: Journal of Electrical Engineering;Vol 20 No 1
Abstract: The distribution systems are transitioning from passive to active with the adaptation of storage, smart-grid, and distribution generation technologies. The reliability of the system can be improved due to the novel controllers, switches, and communication equipment. The common power quality issues are harmonics, signalling voltages, voltage fluctuations, voltage dips, voltage unbalance, power frequency variation, and induced low frequency voltages. These problems can degrade the output power level. To overcome the above problems through the power quality devices like Dynamic voltage restorer (DVR), distribution static compensator (DSTATCOM), and unified power quality conditioner (UPQC). The power quality mitigation technique includes the controller placement and it is named by Hybrid term of fuzzy-genetic controller (FG). Voltage sag, swell, and harmonics, such kind of problems have been analysed in this paper. The results are compared with the existing controllers. The proposed results are load voltage, injected voltage, and generated voltages are taken out. The performance of power quality is analysed through the multi compensating devices, and it is implemented in MMATLAB/SIMULINK. Thus the proposed system can yield the better results instead of the harmonic which is appeared in DVR, DSTATCOM, and UPQC are 0.008231%, 0.0831%, and 0.004308% respectively.
URI: https://dspace.upt.ro/xmlui/handle/123456789/6633
ISSN: 1582-4594
Appears in Collections:Articole științifice/Scientific articles

Files in This Item:
File Description SizeFormat 
BUPT_ART_Williams_f.pdf678.75 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.